SUNSYS B15

SUNSYS B15

15 kW three-phase PV inverter

The solution for

Installations in medium-sized and large commercial buildings

Installations in all types of environmental conditions

The best, high-efficiency performance

Ideal solution for photovoltaic applications on buildings.

The transformerless design offers a conversion efficiency which is amongst the best on the market.

The double tracker series input provides:

optimization of the system’s energy production,

maximisation of the output of extended roof systems with several layers, systems with different orientations, systems with areas of shade,

management of a system divided into sections with different photovoltaic module technologies with a single inverter.

Benefits of the SUNSYS B15 solution

MPPT’s broad voltage tolerance provides excellent flexibility in combination with photovoltaic modules.

The IP65 degree of protection makes it suitable for installation in both indoor and outdoor environments.

Communication and supervision

High-resolution LCD display with a multilingual menu.

Equipped with graphic LCD control panel with a datalogger and RS485 connection for simple and immediate monitoring of the system.

Standard and option features
Technical Data
Input (DC)
Maximum PV power (STC module conditions) 16500 W
Rated voltage 650 VDC
MPPT voltage range 350 to 800 VDC
Number of independent MPPTs 2
Maximum input current 23 A x2
Output (AC)
Power rating 15000 W
Rated voltage 400 Vrms(1) 3ph + N
Rated frequency 50 Hz(1)
Rated current 22 Arms
Total harmonic distortion of current < 3 %
Power factor range 0.8 to 1(2)
Topology Transformerless
Level of efficiency
Maximum efficiency 98.10 %
EU efficiency 97.5 %
General data
Cooling system Smart cooling
Environmental degree of protection (according to EN 62109) IP65
Operating temperature -20 to +60 °C
Sound emission < 55 dB 1 m from inverter
Dimensions (L x D x H) 612 x 278 x 960 mm
Weight 67 kg

(1) The accepted tolerance depends on the country of installation and the regulations in force.