SUNSYS HPS

SUNSYS HPS

Hybrid Power Systems from 40 to 200 kVA

The solution for

Remote unelectrified locations

Locations connected to a disturbed public power grid

Advantages

  • Energy access in areas without a power grid
  • Cost reduction linked to diesel consumption
  • Maximization of diesel generator service life
  • Reduction of CO2 emissions

Reuse and optimization of the existing diesel generator

SUNSYS HPS adapts to the existing gen-set and limits its operation at reduced power. This helps prevent premature wear and significantly reduces maintenance costs.

Simple and easy to install

Compact and centralized solution, the SUNSYS HPS is simple and quick to install. The cost of its implementation is therefore significantly reduced.

Manufacturer’s warranty for global solution

SOCOMEC designs and manufactures the SUNSYS HPS solution in its entirety: converter, AC and DC protection, main LV board.

Extensive power range up to 200 kVA

  • The SUNSYS HPS standard solution is available for power ratings from 40 kVA to 200 kVA
  • Each model is composed of:
  • double conversion system (AC / DC and DC / AC converters),
  • PV charger system (DC / DC converter),
  • battery protection unit,
  • input / output electrical distribution panel.
  • Additional equipment is available on request:
  • battery rack,
  • photovoltaic Field Boxes
  • fully equipped shelter,
  • supervision and monitoring system.
Standard and option features
Technical Data
  Sunsys
HPS
40
Sunsys
HPS
60
Sunsys
HPS
80
Sunsys
HPS
100
Sunsys
HPS
120
Sunsys
HPS
160
Sunsys
HPS
200
AC output nominal power 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA 160 kVA 200 kVA
AC active power 32 kW 48 kW 64 kW 80 kW 100 kW 128 kW 160 kW
AC output voltage 380 / 400 / 415 VAC adjustable / 3 phases + Neutral (± 1%)
AC output frequency 50 / 60 Hz adjustable (± 0.2 Hz)
THDV < 2 %
Crest factor 3:1
Overload 125 % for 10 min / 150 % for 1 min
Max voltage of the PV production 900 VDC
MPPT(1)voltage range of the PV production 480 to 900 VDC
Max photovoltaic power(2) 30 kWp 80 kWp 160 kWp 240 kWp
Efficiency 94 %
Battery configuration 180 cells
Battery type Cyclic sealed lead or open vent
Grid / Genset voltage 380 / 400 / 415 VAC / 3 phases + Neutral (± 15%)
Grid / Genset frequency 50 / 60 Hz (± 5 Hz)
Operational temperature 0 °C to 40 °C depending on the model (25 °C for maximum battery life)
Degree of protection IP20
Dimensions W x D x H 1800 x 845 x 1930 mm 2400 x 845 x 1930 mm 3200 x 845 x 1930 mm
Weight 990 kg 1460 kg 1540 kg 1840 kg

(1) Maximum Power Point Tracking.

(2) Different power outputs are available.