UPS SOCOMEC MODULYS GP - Green Power 2.0 range

UPS SOCOMEC MODULYS GP - Green Power 2.0 range

from 25 to 600 kVA/kW

High availability for your business, cost-effective protection and flexible response to unpredictable demands

MODULYS GP is the innovative solution for protecting critical applications in computer rooms, data centers, banks, healthcare facilities, insurance, telecom.

Advantages

Maximum availability

Optimum reliability

Scalability

Cost optimization

Risk-free maintenance

Fully modular system

Plug-in power module.

Plug-in battery module.

Plug-in bypass module.

Output distribution module.

Top-bottom connection module.

Top-air exhaust module.

Totally redundant design

N+1, N+2 redundancy level.

Designed for no single point of failure.

No centralized parallel control.

Totally independent power modules.

Forever Young’ concept

  • Based on set of modules + electronics-free cabinet.
  • Eliminates end-of-life criticality.
  • Module compatibility guaranteed for 20 years
  • Allows for the implementation of future module technology.

Enhanced serviceability performance

Fast & safe maintenance based on hot-swap modules.

Ready for concurrent maintenance.

Exclusive life cycle extension service program.

Standard and option features

Standard electrical features

Dual input mains.

Internal maintanance bypass.

Backfeed protection: detection circuit.

EBS (Expert Battery System) for battery management.

Battery temperature sensor.

Electrical options

External maintanance bypass.

External battery cabinet.

Ultra-fast charging.

ACS synchronization system.

Standard communication features

User-friendly multilingual interface with color graphic display.

Commissioning wizard.

2 slots for communication options.

MODBUS-RTU

MODBUS-TCP

Communication options

Dry-contact, RS232/485 interfaces.

BACnet/IP interface.

NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

Remote monitoring service

LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24/7.

Technical Data

UPS SYSTEM
Power (Sn) 25 to 200 kVA
Power (Pn) 25 to 200 kW
Number of power modules 1 to 8
Input / output 3/3
Redundant configuration N+x
Parallel configuration up to 600 kW (up to 3 systems)
Input
Voltage 400 V 3ph (340 V to 480 V)
Frequency 50/60 Hz ±10%
Power factor / THDI > 0.99 / < 3%
Output
Voltage 380/400/415 V ±1% 3ph+N
Frequency 50/60 Hz ±0.1%
Voltage distortion < 1% (linear load), < 4% (non-linear load according lEC 62040-3) 
Short-circuit current up to 3 x In  
Overload(1) 125% for 10 minutes, 150% for 1 minute
Crest factor 3:1
Bypass
Voltage rated output voltage ±15% (configurable with from 10% to 20%)
Frequency 50/60 Hz ±2% (configurable for GenSet compatibility)
Efficiency (TÜV SÜD verified)
Online double conversion mode up to 96.5%
Environment
Operating ambient temperature 0 °C to 40 °C (15 to 25 °C for maximum battery life)
Relative humidity 0 to 95% without condensation  
Maximum altitude 1000 m without derating (3000 m max)
Acoustic level at 1 m < 55 dBA
UPS cabinet  
Dimensions (W x D x H) 600 x 890 x 1975 mm
Weight (empty cabinet) 210 kg
Degree of protection IP20
Standards
Safety EN 62040-1, EN 60950-1
EMC EN 62040-2 Class C2
Performance EN 62040-3 (VFI-SS-111)
Product certification CE
Power module
Height 3U
Weight 34 kg
Type Hot plug-in / Hot-swappable
MTBF > 600 000 hours (calculated and verified)
Battery module
Type Acid leak-proof - Long Life batteries      
Protection Single fuse for each battery box
  BATTERY CABINETS
  S modular
battery cabinet
M modular
battery cabinet
High capacity
battery cabinet
Dimensions W x D x H 600 x 890 x 1975 mm 810 x 910 x 1975 mm 810 x 910 x 1975 mm
Number of battery bays 12 12 Blocks

(1) Conditions appl