UPS SOCOMEC MASTERYS IP+

UPS SOCOMEC MASTERYS IP+

from 10 to 80 kVA

High reliability in harsh industrial environments

Specially engineered to power and protect typical industrial equipments such as motors, motor speed drivers, lamps, non linear loads, welding equipments, power supplies, MASTERYS IP+ is also perfectly able to supply control equipments like programmable controllers, sensors and measurement apparatus and integrates perfectly into the most demanding industrial environments.

The solution for

Industrial processes

Services

Medical

Advantages

Designed for the most demanding applications

Designed to protect industrial processes.

A compact solution with isolation transformer and integrated batteries.

Robust enclosure (2 mm thick heavy steel frame).

Floor anchoring (to prevent tilting).

IP31 and IP52 protection degree for harsh environments with easy replaceable dust filters.

Wide input voltage tolerance from -40% up to +20% of nominal voltage

Double EMC immunity compared to UPS international standard IEC 62040-2.

Process continuity

Frontal access for input/output cabling, spares replacement and preventative maintenance.

Scalable power and high availability (using redundancy), with the facility to parallel up to 6 units.

Easy integration into industrial networks

Input power factor > 0.99 and input current harmonic distortion < 3% thanks to IGBT rectifier.

Compatible with Open Vented Lead Acid, Valve Regulated Lead Acid (VRLA) and Nickel Cadmium batteries.

User-friendly multilingual interface with graphic display.

Flexible communication boards for every industrial communication need: dry contacts, MODBUS, PROFIBUS, etc.

Fully compatible with generator sets.

For industrial loads

100 % non-linear loads.

100 % unbalanced loads.

100 % “6-pulse” loads (motor speed drivers, welding equipment, power supplies…).

Motors, lamps.

Standard and option features

Standard electrical features

Dual input mains.

Internal maintanance bypass.

Backfeed protection: detection circuit.

EBS (Expert Battery System) for battery management.

Electrical options

Long-life batteries.

External battery cabinet (degree of protection up to IP32).

External temperature sensor.

Additional battery chargers.

Additional transformer.

Parallel kit.

Cold start.

ACS synchronization system.

Neutral creation kit for mains without neutral.

Tropicalization and anti-corrosion protection for electrical boards.

Standard communication features

Multilanguage graphic display.

Dry-contact interface.

MODBUS/JBUS RTU.

Embedded LAN interface (web pages, email).

2 slots for communication options.

Communication options

Remote mimic panel.

Profibus.

MODBUS TCP.

NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance

LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC

Technical Data

Internal architecture


Energy storage option: ultracapacitor

Ultracapacitor could be a suitable battery replacement in special situations where a long back-up time is not required. This solution is targeted specifically to ride-through frequent voltage dips and short power outages, or simply bridge the startup of a generator, or where ambient temperatures could compromise battery lifetime. This would result in a highly reliable energy storage system that would require no maintenance.

Advantages

Extremely long lifetime: 15 years with virtually unlimited cycling.

High-reliability – No maintenance.

Wide temperature range up to 45 °C.

Ultra rapid charging.

Battery-free, lead-free and environment-friendly


Sn [kVA] 10 15 20 30 40 60 80
Pn [kW] - 3/1 9 13,5 18 27 32 48  
Pn [kW] - 3/3 9 13,5 18 27 32 48 64
Parallel configuration(1) up to 6 units
Input
Rated voltage 400 V (3ph + N)
Voltage tolerance ± 20%(3) (up to -40% @ 50% of rated power)
Rated frequency 50/60 Hz
Frequency tolerance ± 10%
Power factor / THDI(2) 0.99 / < 3%
Output
Rated voltage 1ph + N: 230 V (can be configured 220/240 V)
3ph + N: 400 V (380/415 V configurable) (3)
Voltage tolerance ± 1%
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generating set)
Voltage distortion < 1 % 
Overload (2) 125% for 10 minutes, 150% for 1 minute 
Crest factor 3:1 (complying with IEC 62040-3)
Bypass
Rated voltage 1ph + N: 230 V, 3ph + N: 400 V
Voltage tolerance ± 15% (configurable from 10% to 20% with generating set)
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generating set)
Environment
Operating ambient temperature from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity 0 % - 95 % without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m
(ISO 3746)
< 52 dBA < 55 dBA < 65 dBA
Dimension and weight - UPS single cabinet  
Dimensions (3/1) W x D x H 600 x 800 x 1400 mm 1000 x 835 x
1400 mm
-
Dimensions (3/3) W x D x H 600 x 800 x 1400 mm 1000 x 835 x
1400 mm
Weight (3/1) 230 kg 250 kg 270 kg 330 kg 490 kg 540 kg  -
Weight (3/3) 230 kg 250 kg 270 kg 320 kg 370 kg 500 kg 550 kg
Degree of protection IP31 and IP52 (according to IEC 60529)
Colours RAL 7012 
Standards
Safety EN 62040-1 (TÜV SÜD certified), EN 60950-1
Type and performance EN 62040-3 [VFI-SS-111]
EMC EN 62040-2 (2nd Edition)
Product declaration CE

(1) With transformer on input/bypass side.

(2) For source THDV < 2 % and nominal load.

(3) Three-phase 220-230-240 V from 15 to 40 kVA.

More technical data on the dedicated sales document