ITYS ES

ITYS ES

from 1000 to 3000 VA Solutions for supplying MV/LV transformer cabins

The solution for

Control devices

Electric lines

Advantages

High protection and high availability

Range of compact UPS systems available in 1000, 2000 and 3000 VA models with on-line double conversion technology (VFI).

Permanent regulation of the output voltage and frequency. This technology is compatible with all IT and industrial applications and operating environments, installations with generator sets included.

Wide tolerance on input voltage ensures that switchovers to battery mode are infrequent, significantly prolonging battery lifetime.

The automatic bypass device switches over in zero time in the event of overload or failure, guaranteeing uninterrupted services.

Tropicalization and anti-corrosion protection for electrical boards.

Straightforward to install and easy to use

Shipped ready for connection with internal batteries connected and charged.

With the manual bypass option, it is easy to install without any special plant engineering preparation, as it is equipped with built-in thermal protection.

The LED monitoring/control panel and a buzzer make the equipment extremely easy and intuitive to use. The graphic indicating the power distribution path shows at a glance whether or not the system is working as it should.

Battery efficiency can be tested via the control panel or using dedicated software.

Operating efficiency and versatility

Suitable for protecting critical devices in the industrial field.

The standard equipment and communication accessories have been specially designed to satisfy the typical needs of installation or use in transformer cabins.

n situations where automatic power management procedures are required, the communication software can be used to programme scheduled start-up and shutdown times.

Restarting the UPS from the battery to power the DG before closing the main isolator.

Standard and option features

Standard communication features

LOCAL VIEW: ideal point-to-point software for UPS monitoring and shutdown of Windows®, Linux and MAC OS X® operating systems (standard for all models).

MODBUS/JBUS RTU (RS 232).

Communication options

NET VISION: professional network adapter for monitoring and controlling UPS units from a remote location (option for all models).

Dry contact interface.

Technical Data

Manual bypass (option)

Specially designed for ITYS ES, the manual bypass option enables:

simplified installation: connection to the system is made with industrial grade terminals, while connection to the UPS is via the pre-wired plug and socket supplied.

easy maintenance and uninterrupted operation: thanks to the manual bypass isolator it is possible to service or replace the UPS while maintaining the power supply to the devices downstream in complete safety for the operator. This operation has been specially devised to be simple to carry out, even in an emergency.

ncreased level of equipment immunity to surge voltages, typical for this type of application, thanks to suitable surge arrestors included in addition to standard UPS protection.

Programmable clean contacts board (option)

Dedicated interface with clean contacts, can be installed on the rear slot: gives the status of the UPS with five potential-free contacts and provides an input for remote emergency stopping (EPO).

  ITYS ES - UPS
Item Code ITYS ES 1k0 ITYS ES 2k0 ITYS ES 3k0
Sn 1000 VA 2000 VA 3000 VA
Pn 700 W 1400 W 2100 W
Input / output 1/1
Input
Rated voltage 230 V
Voltage tolerance 160-300 V (up to 110 V at 60% of the load)
Rated frequency 50/60 Hz
Power factor 0.98
Output
Rated voltage 230 V (can be set to 220/240 V)
Voltage tolerance ± 1.5%
Rated frequency range of synchronism 46-54 Hz
Frequency stability (for 50 Hz) 50 Hz ± 0.2 in battery mode
Overload up to 150 % for 30 seconds
Crest factor 3:1
Connections 4 x IEC 320 6 x IEC 320 4 x IEC 320
+ terminals
Batteries
Type sealed lead-acid maintenance free - expected lifetime 3-5 years
Back-up time at 75% of the rated load(1) 10 min 17 min 9 min
Sized for a back-up time of 115 min @ 50 W 154 min @ 100 W 216 min @ 150 W
Back-up time(2) + switching back on 60 min @ 50 W 60 min @ 100 W 60 min @ 150 W
Battery test
Communication
Interfaces RS232 (DB9 connector) MODBUS protocol
Communication slots
Modem/ADSL protection
Efficiency
Online mode up to 90 %
Environment
Ambient service temperature 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime)
Relative humidity 0 to 90% non-condensing
Maximum altitude 1000 m without de-rating (3000 m max)
Noise level at 1 m 45 dBA
UPS cabinet
Dimensions W x D x H 145 x 400 x 220 mm 192 x 460 x 350 mm
Weight 14 kg 34 kg 34/16 kg
Degree of protection IP20 (according to IEC 60529)
Colours Cabinet 430C, front 431C
Standards
Safety EN 62040-1
EMC EN 62040-2 Equipped with input filters to suppress atmospheric interference
Product certification CE


  ITYS ES - Manual bypass(3)
Sn 1000 VA 2000 VA 3000 VA
Input
Type of terminals CBD6
Wire size 6 mm2 max
Bypass
Switching positions 1: UPS - 2: MAINS
Switching time 6 ms max
Load output
Type of terminals CBD6
Wire size 6 mm2 max
UPS supply output
Type of socket IEC 320 10 A IEC 320 16 A
Surge arrestors (on request)
Type “L” in compliance with CEI EN 61643-11
L/N pulse current 40 kA (8/20) max
VAC N/GND 255 V max
VAC L/N 320 V max